Successful operations of quantum-logic-based 27Al+ ion optical clocks have been reported by several groups. But there are still several lingering issues. The first is the proper choice of logic ions, and the second is the proper quantum state identification methods. In this paper, the advantage of using 25Mg+ as the logic ion to ensure smaller time-dilation shift is discussed. We also compare several statistical methods to identify the 27Al+ ion clock state. Finally, we report the observation of the 27Al+ ion 1S0 →3 P0 clock transition based on 25Mg+–27Al+ ion pair. As a precondition for quantum logic spectroscopy (QLS), both the stretch (STR) mode and the center of mass (COM) mode of the 27Al+ and 25Mg+ ion pair are cooled to the vibrational ground state by Raman sideband cooling. The mean phonon number is measured to be 0.10(1) for the STR mode and 0.01(1) for the COM mode, respectively. The heating rate is evaluated to be 0.23(5) phonons/s for the STR mode and 3.0(7) phonons/s for the COM mode, respectively. The clock transition is observed with a full-width-half-maximum (FWHM) of 38(4) Hz at 22 ms interrogation time.

期刊名:Applied Physics B

/卷:126

页码:129

发表时间:2020

DOI: 10.1007/s00340-020-07479-4